GA10D Series 10~12W 4KVac Isolation Regulated Output AC-DC Converter (Module)

Product Description

10~12W 4KVac Isolation Regulated Output AC to DC Power Conversion


Features


  • Universal input 90~264VAC.

  • High efficiency up to 85%.

  • Protection: short circuit/over load.

  • Fully encapsulated plastic case.

  • 3 years warranty.

  • ROHS compliant.




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency
(W) (VDC) (mA) (mV) max (Note) (TYP %)
GA10D-S03 6.6 3.3 2000 150 72
GA10D-S05 10.0 5 2000 150 75
GA10D-S10 10.0 10 1000 150 80
GA10D-S12 12.0 12 1000 150 82
GA10D-S15 12.0 15 800 150 82
GA10D-S24 12.0 24 500 150 85
GA10D-S36 12.0 36 330 240 85
GA10D-S48 12.0 48 250 240 85

Note:
1. Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.
2. Only GA10D-S05-A recognized by CB.



Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Vo, Io nom   100 ~ 240   Vac
Voltage Range Vo, Io nom AC in 90   264 Vac
DC in 120   370 Vdc
Line Frequency Vi nom, Io nom 47 50/60 63 Hz
Inrush Current Io nom Vi: 115VAC     10 A
Vi: 230VAC     20 A


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy Vi nom, Io nom 3.3....V Models     ± 3 %
10....48V Models     ± 2 %
Minimum Load Vi nom 0     %
Line Regulation Io nom, Vi min....i max   ± 0.2   %
Load Regulation Vi nom, Io min....o nom 3.3V Models   ± 1.0   %
5....48V Models   ± 0.5   %
Transient Recovery time Vi nom, Io nom = ← → 0.5 Io nom   1000   us
Protection Over Load Above 110% rated output power
Protection type: Recovers automatically after fault condition is removed
Short Circuit Recovers automatically after fault condition is removed


General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency Vi nom, Io nom   65   KHz
Isolation Voltage Input / Output 4KVac / 5mA / 5Secs
Isolation Resistance Input / Output, @500 Vdc 100    
Operating Temperature Refer to Temperature Derating Graph -40   +70
Storage Temperature Non Operational -40   +105
Relative Humidity Vi nom,Io nom     95 % RH
Safety Standards Design refer to UL60950-1, IEC60950-1
EMI Conduction & Radiation EN55022, CLASS B (See Fig. 1 for recommended circuit)
EMS Immunity EN61000 (See Fig. 1 for recommended circuit)
Dimension L 50.8 x W 25.4 x H 23.5 mm
Cooling Free air convection



Dimension 




 Files Download      GA10D-Series.pdf



Certification


FEEDBACK

GA003/GB003/GC003 Series 3W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA005/GB005/GC005 Series 5~6W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA5A Series 5~6W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA5E Series 1~5W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA007 Series 7W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA010 Series 10W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA015 Series 13~19W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA25D Series 20~27W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA025 Series 24~27W 3KVac Isolation Regulated Output AC-DC Converter

GA025-SXX Series 14~25W 3KVac Isolation Regulated Output AC-DC Converter

GA030 Series 26~48W 3KVac Isolation Regulated Output AC-DC Converter (Module)