GA5E Series 1~5W 3KVac Isolation Regulated Output AC-DC Converter (Module)

Product Description

1~5W AC to DC Power Conversion with 1.0" x 1.0" x 0.64" Package


Features


  • Ultra compact size 1.0" x 1.0" x 0.64"Package.

  • Universal input 90~264VAC.

  • High efficiency up to 85%.

  • Protection: short circuit/overload/over voltage.

  • Fully encapsulated plastic case.

  • UL/cUL/IEC/EN60950-1 , 62368-1 approved.

  • EMC standard of EMI EN55032:2015 approved.

  • EMC standard of EMS EN55024:2010 approved.

  • 3 years warranty.

  • ROHS compliant.




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency Max. Capacitive Load
(W) (VDC) (mA) (mV) max (Note) (TYP %) (μF)
GA5E-S03-X 5.0 3.3 1515 60 73 2200
GA5E-S05-X 5.0 5 1000 60 80 1000
GA5E-S09-X 5.0 9 555 90 81 300
GA5E-S12-X 5.0 12 416 120 81 160
GA5E-S15-X 5.0 15 333 150 82 100
GA5E-S24-X 5.0 24 208 240 82 43
GA5E-S48-X 5.0 48 104 480 84 10

Note:
X= ONE digit representing the output power (W) The output power is rising in steps of 1W from 1W to the max. output Power; 

When the output power is maximum power, X is omitted.  E.g:3W=GA5E-S05-3, GA5E-S15-3 ; 5W=GA5E-S05, GA5E-S15




Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Vo, Io nom   100 ~ 240   Vac
Voltage Range Vo, Io nom AC in 90   264 Vac
DC in 120   370 Vdc
Line Frequency Vi nom, Io nom 47 50/60 63 Hz
Inrush Current Io nom Vi: 115VAC     10 A
Vi:230VAC     20 A
Input Fuse VDE / UL / CCC  FUSE 2.5A /250V (Slow blow)


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy Vi nom,
Io nom
3.3V, 5V Models     ± 3 %
9....48V
Models
    ± 2
Minimum Load Vi nom 0     %
Line Regulation Io nom,
Vi min...Vi max
    ± 1.0 %
Load Regulation       ± 1.0 %
Transient Recovery Time Vi nom, Io nom = ← → 0.5 Io nom   1000   us
Protection Overload Above 110% rated output power
Protection type: Recovers automatically after fault condition is removed
Short Circuit Recovers automatically after fault condition is removed
Over Voltage 120%-150% rated output Voltage
Protection type: Zener diode clamp

Notes:
Ripple & noise is measured by using 20 MHz bandwidth, measured with a 10uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.



General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency Vi nom, Io nom   65   KHz
Isolation Voltage Input / Output 3KVac / 5mA / 5Secs
Isolation Resistance Input / Output, @500 Vdc 100    
Operating Temperature Refer to Temperature Derating Graph -25   +70
Storage Temperature Non Operational -40   +85
Relative Humidity Vi nom, Io nom     95 % RH
Safety Standards UL 62368-1,IEC 62368-1 approved
EMI Conduction & Radiation Compliance to EN55032,CLASS B
EMS Immunity Compliance to EN61000
Dimension L 25.4 x W 25.4 x H 16.1 mm
Cooling Free air convection    


Dimension





 Files Download      GA5E-Series.pdf



Certification




FEEDBACK

GA5A Series 5~6W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA007 Series 7W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA010 Series 10W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA10D Series 10~12W 4KVac Isolation Regulated Output AC-DC Converter (Module)

GA015 Series 13~19W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA25D Series 20~27W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA025 Series 24~27W 3KVac Isolation Regulated Output AC-DC Converter

GA025-SXX Series 14~25W 3KVac Isolation Regulated Output AC-DC Converter

GA030 Series 26~48W 3KVac Isolation Regulated Output AC-DC Converter (Module)