GA005/GB005/GC005 Series 5~6W 3KVac Isolation Regulated Output AC-DC Converter (Module)

Product Description

5W 3KVac Isolation AC to DC Power Conversion


Features


  • Universal input 90~264VAC.

  • High efficiency up to 82%.

  • Protection: short circuit/overload/over voltage.

  • Internal input filter.

  • 3 years warranty.

  • ROHS compliant.




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency
(W) Vdc mA (mV) max (Note2) % (TYP)
GX005-S03 4.0 3.3 1200 100 72
GX005-S05 5.0 5 1000 100 75
GX005-S06 5.1 6 850 100 75
GX005-S07 5.1 7 725 100 75
GX005-S08 5.0 8 625 100 75
GX005-S09 5.4 9 600 100 78
GX005-S10 6.0 10 600 100 78
GX005-S12 6.0 12 500 100 80
GX005-S13 6.0 13 460 150 80
GX005-S14 6.0 14 425 150 80
GX005-S15 6.0 15 400 150 80
GX005-S16 6.0 16 375 150 80
GX005-S18 6.0 18 333 200 81
GX005-S24 6.0 24 250 240 82
GX005-S27 6.0 27 220 240 82
GX005-S36 6.0 36 167 240 82
GX005-S48 6.0 48 125 240 82

Notes:
1. "X" Represent module version
  A: Represent module version with enclosure;
  B: Represent open frame version without enclosure;
  C: Represent wired moduleversion with enclosure.
2. Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.
3. Only GA005 series recognized by UL & CB.



Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Vo, Io nom   100 ~ 240   Vac
Voltage Range Vo, Io nom AC in 90   264 Vac
DC in 120   370 Vdc
Line Frequency Vi nom. Io nom 47 50/60 63 Hz
Inrush Current Io nom Vi: 115VAC     10 A
Vi: 230VAC     20 A

Input Current 

(Full load)

110mA Max. (115Vac) 70mA Max. (230Vac)
Input Fuse VDE / UL / CCC  FUSE 2.5A / 250V (Slow blow).


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy Vi nom,
Io nom
3.3V, 5V Models     ± 3 %
12....48V Models     ± 2
Minimum Load Vi nom 0     %
Line Regulation Io nom,
Vi min…Vi max
  ± 1   %
Load Regulation Vi nom, Io min....Io nom   ± 2   %
Transient Recovery Time Vi nom, Io nom = I ← → 0.5 Io nom   1000   us
Protection Overload Above 110% rated output power
Protection type: Recovers automatically after fault condition is removed
Short Circuit Recovers automatically after fault condition is removed
Over Voltage 120%-150% rated output Voltage
Protection type: Zener diode clamp


General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency Vi nom, Io nom   65   KHz
Isolation Voltage Input / output 3.0KVac / 5mA / 5Secs
Isolation Resistance Input / output,@500Vdc 100    
Ambient Temperature Operating at Vi nom, Io nom -20   +70
Derating Vi nom, Io nom +51 to 71℃     2 % / ℃
Storage Temperature Nom operational -40   +85
Relative Humidity Vi nom,Io nom     95 % RH
Dimension GA005 / GC005 L 50.80 x W 25.40 x H 17.02
GB005 L 48.5 x W 23.0 x H 16.0
mm
Cooling Free air convection    



Dimension






 Files Download       GA-B-C005-Series.pdf




Certification





FEEDBACK

GA003/GB003/GC003 Series 3W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA007 Series 7W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA5A Series 5~6W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA5E Series 1~5W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA010 Series 10W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA10D Series 10~12W 4KVac Isolation Regulated Output AC-DC Converter (Module)

GA015 Series 13~19W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA25D Series 20~27W 3KVac Isolation Regulated Output AC-DC Converter (Module)

GA025-SXX Series 14~25W 3KVac Isolation Regulated Output AC-DC Converter

GA025 Series 24~27W 3KVac Isolation Regulated Output AC-DC Converter

GA030 Series 26~48W 3KVac Isolation Regulated Output AC-DC Converter (Module)