GB200 Series 200W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

Product Description

200W 3KVac Isolation Single Output Open Frame AC to DC Power Conversion


Features


  • Universal input 90~264VAC.

  • High efficiency at 93% typical.

  • Protection: short circuit/overload/over voltage/over temperature.

  • Built-in active PFC function.

  • 5" x 3" miniature size.

  • No load power consumption<0.5W.

  • 3 years warranty.




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Voltage Output Current Ripple & Noise Efficiency Output Power(W)
V MAX mVp-p(Max) (note) %(TYP) Rated
GB200-S12 12 16.7A 200 92 200.4
GB200-S15 15 13.4A 200 92 201
GB200-S24 24 8.4A 250 93 201.6
GB200-S27 27 7.5A 250 93 202.5
GB200-S48 48 4.2A 350 93 201.6


Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Io nom   100 ~ 240   Vac
Voltage Range Io nom 90   264 Vac
Io nom 127   370 Vdc
Frequency   47 50/60 63 Hz
Inrush Current At 115Vac     30 A
At 230Vac     60 A
Input Over-Current Protection VDE/UL/CCC  FUSE 3.15A/250V
Power Factor PF> 0.93 / 230Vac  PF> 0.98 / 115Vac at full load


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy Vi nom, Io nom     ± 2 %
Minimum Load Vi nom 0      
Line Regulation Io nom, Vi min…Vi max   ± 1.0   %
Load Regulation Vi nom, Io min…Io nom   ± 2.0   %
Protection Over Load 115% -150% rated output power
Protection type: Shut off o/p voltage, re-power on to recover
Over Voltage 120%-150% rated output Voltage
Protection type: Shut off o/p voltage, re-power on to recover
Short circuit Protection type: Shut off o/p voltage, re-power on to recover
Over temperature Protection type: Shut off o/p voltage, re-power on to recover

Note:
Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor across each output by full load.



General Specifications


Parameters Conditions Min Typ Max Units
MTBF MIL-HDBK-217F(25℃) 100,000     Hrs
Isolation Voltage Input To Output 3000V AC 5mA/5Secs  
Input To Ground 2000V AC 5mA/5Secs  
Output To Ground 500V AC 5mA/5Secs  
Size   127x76.2x36.0(5.0x3.0x1.42) Mm (inches)
Weight     327   g
Operating Temperature With Derating -20   +70
Storage Temperature   -45   +85


Dimension





 Files Download     GB200-Series.pdf



Certification




FEEDBACK

GS1 Series 1W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GS3 Series 3W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GS5 Series 5W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GP12 Series 10~15W 4KVac Isolation Single Output AC-DC Converter (Open Frame)

GB015 Series 10~19W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB020/GB030 Series 20~30W 3KVac Isolation Single & Dual Output AC-DC Converter (Open Frame)

GP25D Series 20~27W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB40A Series 40W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB040 Series 40W 3KVac Isolation Dual & Triple Output AC-DC Converter (Open Frame)

GB60A Series 60W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB100 Series 100W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB100A Series 100W 3KVac Isolation 3" X 2" Miniature Size AC-DC Converter

GB150 Series 150W 3KVac Isolation Single Output AC-DC Converter (Open Frame)