GB020/GB030 Series 20~30W 3KVac Isolation Single & Dual Output AC-DC Converter (Open Frame)

Product Description

20~30W 3KVac Isolation Single & Dual Output Open Frame AC-DC Power Conversion 


Features


  • Universal input 90-264VAC.

  • High efficiency up to 88%.

  • Protection: short circuit/overload/over voltage.

  • Meet EMI EN55022 & EMS EN55024 standard.

  • Internal input filter.

  • 3 years warranty.

  • ROHS compliant.




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency
(W) (VDC) (mA) (mV) max(Note) (TYP %)
GB030-S03 20 3.3 6000 100 70
GB030-S05 30 5 6000 100 75
GB030-S12 30 12 2500 100 80
GB030-S15 30 15 2000 150 84
GB030-S24 30 24 1250 240 86
GB030-S48 30 48 625 240 88
GB030-D05 30 ± 5 ± 3000 100 75
GB030-D12 30 ± 12 ± 1250 100 78
GB030-D15 30 ± 15 ± 1000 150 80
GB020-D0503 20 V1=+5 / V2=+3.3 +3000/+1500 150 65
GB030-D0512 30 V1=+5 / V2=+12.0 +3000/+1250 150 75


Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Vo, Io nom   100 ~ 240   Vac
Voltage Range Vo, Io nom AC in 90   264 Vac
DC in 120   370 Vdc
Line Frequency Vi nom, Io nom 47 50/60 63 Hz
Inrush Current Io nom Vi: 115VAC     10 A
Vi: 230VAC     20 A
Input Fuse VDE/UL/CCC  FUSE 2.5A/250V (Slow blow)


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy Vi nom, Io nom
(Main output)
3.3V,5V Models     ± 3 %
12...48V Models     ± 2 %
Supplement Output     ± 5 %
Minimum Load Vi nom Single Output Models 0     %
Dual Output Models
(each output)
20     %
Line Regulation Io nom, Vi min…Vi max   ± 1   %
Load Regulation Io min~Io nom Single Output Models   ± 2   %
Dual Output Models   ± 5   %
Protection Over Load Above 110% rated output power
Protection type:
Recovers automatically after fault condition is removed
Over Voltage 120%-150% rated output Voltage
Protection type: Zener diode clamp
Short circuit Recovers automatically after fault condition is removed

Note:
Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor across each output by full load.



General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency Vi nom, Io nom   65   KHz
Isolation Voltage Input / Output 3KVac / 5mA / 5Secs
Isolation Resistance Input / Output, @500 Vdc 100    
Operating Temperature Operating at Vi nom, Io nom -20   +70
Derating Vi nom,Io nom+51 to 71℃     2 %/℃
Storage Temperature Non Operational -40   +85
Relative Humidity Vi nom, Io nom     95 % RH
Dimension L101.60 x W50.80 x H31.0
Cooling Free air convection



Dimension




 Files Download      GB020-GB030-Series.pdf



Certification




FEEDBACK

GS1 Series 1W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GS3 Series 3W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GS5 Series 5W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GP12 Series 10~15W 4KVac Isolation Single Output AC-DC Converter (Open Frame)

GB015 Series 10~19W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GP25D Series 20~27W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB40A Series 40W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB040 Series 40W 3KVac Isolation Dual & Triple Output AC-DC Converter (Open Frame)

GB60A Series 60W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB100 Series 100W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB100A Series 100W 3KVac Isolation 3" X 2" Miniature Size AC-DC Converter

GB150 Series 150W 3KVac Isolation Single Output AC-DC Converter (Open Frame)

GB200 Series 200W 3KVac Isolation Single Output AC-DC Converter (Open Frame)