RM14 Series Inverter Transformer
Product Description
Inverter Transformer
Description:
- Inverter transformer is a kind of work in DC to AC transformer under the module 
- Used in solar energy,vehicle power supply system, uninterruptible power supply, etc. 
- Flyback topology structure 
- Operate at 57kHz with 20~55 VDC input 
- Rectified sine wave output 
- Maximum Power:100W 
- Hipot voltage: 3000Vrms,one minute isolation primary to secondary 
- 1500Vrms,one minute isolation windings to core 
- Custom designs available 
Other
- Operating temperature range: -40℃ to +85℃ 
- Storage temperature range: -40℃ to +85℃ 
- RoHS Compliant version is available 
Electrical Specifications
| Part Number | Turn Ratio Pri:Sec | L ① (uH±10%) | Input | LK ②max(uH) | Output Voltage | DCR ③ max(Ohms) | L at Ipk(10A) ④ min(uH) | |
|---|---|---|---|---|---|---|---|---|
| Pri | Sec | |||||||
| 14RM-5501ENL | 1:7 | 55.0 | 20~55 VDC,57KHZ | 2.95uH | 230VAC,100W | 0.0475 | 0.36 | 44.0 | 
| 14RM-5502ENL | 1:4 | 55.0 | 20~55 VDC,57KHZ | 2.75uH | 110VAC,100W | 0.0480 | 0.19 | 38.5 | 
① L(NOM)=Nominal Inductance is for pri winding, measured at 150KHz,1.0Vrms
 ② Leakage inductance measured at 150KHz,1.0Vrms between Pri other pins shorted
③ DCR for the primary is with windings connected in parallel
④ Ipk is the peak current drawn at minimum input voltage
Dimension
Files Download RM14-Series.pdf
Certification