Availability: | |
---|---|
Quantity: | |
8~22Watt Isolated & Non-isolated Non-Dimmable PFC LED Driver
Features :
Wide Input Voltage 90 to 264VAC,47 to 63Hz
High Efficiency Up To 88%
Protection:Short Circuit /Over current/Over voltage
Meet EMI EN55022 & EMS EN55024 standard
Power Factor Correction
3 Years Warranty
ROHS Compliant
Part Number | Output Wattage | Constant Current Region | Constant Current | Efficiency %(TYP) | |
---|---|---|---|---|---|
(W) | (V) | (mA) | T8P | T8AP | |
T8(A)P-420-0200 | 8 | 36.0-43.2 | 200 | 88 | 85 |
T8(A)P-420-0240 | 9 | 36.0-43.2 | 240 | 88 | 85 |
T8(A)P-420-0360 | 12 | 36.0-43.2 | 360 | 88 | 85 |
T8(A)P-420-0400 | 16 | 36.0-43.2 | 400 | 88 | 85 |
T8(A)P-420-0480 | 18 | 36.0-43.2 | 480 | 88 | 85 |
T8(A)P-550-0200 | 11 | 42.0-55.0 | 200 | 88 | 85 |
T8(A)P-550-0240 | 13 | 42.0-55.0 | 240 | 88 | 85 |
T8(A)P-550-0360 | 20 | 42.0-55.0 | 360 | 88 | 85 |
T8(A)P-550-0400 | 22 | 42.0-55.0 | 400 | 88 | 85 |
Note:(A) is Isolated Series. For example: T8AP-420-0200 Isolated, T8P-420-0200 Non Isolated
Parameters | Conditions | Min | Typ | Max | Units | |
---|---|---|---|---|---|---|
Rated input voltage | Vo,Io nom | 100~240 | Vac | |||
Voltage Range | Vo,Io nom | 90 | 264 | Vac | ||
Line Frequency | Vi nom,Ionom | 47 | 50/60 | 63 | Hz | |
Inrush Current | Io nom | Vi:115VAC | 10 | A | ||
Vi:230VAC | 20 | A | ||||
Power Factor (T8P) | PF> 0.80 / 115Vac,230Vac at full load | |||||
Power Factor (T8AP) | PF> 0.90 / 115Vac,230Vac at full load |
Parameters | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|
Isolation Voltage(T8AP) | Input / Output | 3KVac/ 5mA/5Secs | |||
Current Accuracy | Vi=110-240Vac | ±3 | ±5 | % | |
Operating Temperature | Operating at Vi nom, Io nom | -20 | +50 | ℃ | |
Protection | Over Current | >108% rated output power (Constant current limiting) | |||
Protection type: Recovers automatically after fault condition is removed | |||||
Over Voltage | 120%-150% rated output Voltage | ||||
Protection type: Recovers automatically after fault condition is removed | |||||
Short circuit | Recovers automatically after fault condition is removed |
Files Download T8-A-P-Series.pdf
Certification
8~22Watt Isolated & Non-isolated Non-Dimmable PFC LED Driver
Features :
Wide Input Voltage 90 to 264VAC,47 to 63Hz
High Efficiency Up To 88%
Protection:Short Circuit /Over current/Over voltage
Meet EMI EN55022 & EMS EN55024 standard
Power Factor Correction
3 Years Warranty
ROHS Compliant
Part Number | Output Wattage | Constant Current Region | Constant Current | Efficiency %(TYP) | |
---|---|---|---|---|---|
(W) | (V) | (mA) | T8P | T8AP | |
T8(A)P-420-0200 | 8 | 36.0-43.2 | 200 | 88 | 85 |
T8(A)P-420-0240 | 9 | 36.0-43.2 | 240 | 88 | 85 |
T8(A)P-420-0360 | 12 | 36.0-43.2 | 360 | 88 | 85 |
T8(A)P-420-0400 | 16 | 36.0-43.2 | 400 | 88 | 85 |
T8(A)P-420-0480 | 18 | 36.0-43.2 | 480 | 88 | 85 |
T8(A)P-550-0200 | 11 | 42.0-55.0 | 200 | 88 | 85 |
T8(A)P-550-0240 | 13 | 42.0-55.0 | 240 | 88 | 85 |
T8(A)P-550-0360 | 20 | 42.0-55.0 | 360 | 88 | 85 |
T8(A)P-550-0400 | 22 | 42.0-55.0 | 400 | 88 | 85 |
Note:(A) is Isolated Series. For example: T8AP-420-0200 Isolated, T8P-420-0200 Non Isolated
Parameters | Conditions | Min | Typ | Max | Units | |
---|---|---|---|---|---|---|
Rated input voltage | Vo,Io nom | 100~240 | Vac | |||
Voltage Range | Vo,Io nom | 90 | 264 | Vac | ||
Line Frequency | Vi nom,Ionom | 47 | 50/60 | 63 | Hz | |
Inrush Current | Io nom | Vi:115VAC | 10 | A | ||
Vi:230VAC | 20 | A | ||||
Power Factor (T8P) | PF> 0.80 / 115Vac,230Vac at full load | |||||
Power Factor (T8AP) | PF> 0.90 / 115Vac,230Vac at full load |
Parameters | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|
Isolation Voltage(T8AP) | Input / Output | 3KVac/ 5mA/5Secs | |||
Current Accuracy | Vi=110-240Vac | ±3 | ±5 | % | |
Operating Temperature | Operating at Vi nom, Io nom | -20 | +50 | ℃ | |
Protection | Over Current | >108% rated output power (Constant current limiting) | |||
Protection type: Recovers automatically after fault condition is removed | |||||
Over Voltage | 120%-150% rated output Voltage | ||||
Protection type: Recovers automatically after fault condition is removed | |||||
Short circuit | Recovers automatically after fault condition is removed |