Availability: | |
---|---|
Quantity: | |
GA030 Series
YDS
26~48W 3KVac Isolation Regulated Output AC to DC Power Conversion
Universal input 90~264VAC.
High efficiency up to 88%.
Protection: short circuit/overload/over voltage.
Fully encapsulated plastic case.
Internal input filter.
3 years warranty.
ROHS compliant.
Part Number | Output Wattage | Output Voltage | Output Current | Ripple & Noise | Efficiency |
---|---|---|---|---|---|
(W) | (VDC) | (mA) | (mV) max (Note) | (TYP %) | |
GA030-S03 | 26.4 | 3.3 | 8000 | 150 | 72 |
GA030-S05 | 40.0 | 5 | 8000 | 150 | 75 |
GA030-S06 | 40.0 | 6 | 6650 | 150 | 75 |
GA030-S07 | 40.0 | 7 | 5700 | 150 | 80 |
GA030-S08 | 40.0 | 8 | 5000 | 150 | 80 |
GA030-S09 | 40.0 | 9 | 4400 | 150 | 82 |
GA030-S10 | 40.0 | 10 | 4000 | 150 | 82 |
GA030-S12 | 42.0 | 12 | 3500 | 150 | 84 |
GA030-S13 | 42.0 | 13 | 3200 | 150 | 84 |
GA030-S14 | 42.0 | 14 | 3000 | 150 | 84 |
GA030-S15 | 42.0 | 15 | 2800 | 150 | 84 |
GA030-S16 | 42.0 | 16 | 2625 | 150 | 85 |
GA030-S18 | 42.0 | 18 | 2300 | 150 | 85 |
GA030-S24 | 42.0 | 24 | 1750 | 240 | 86 |
GA030-S27 | 42.0 | 27 | 1550 | 240 | 86 |
GA030-S36 | 43.2 | 36 | 1200 | 240 | 86 |
GA030-S48 | 48.0 | 48 | 1000 | 240 | 88 |
GA030-D05 | 40.0 | ± 5 | ± 4000 | 150 | 75 |
GA030-D12 | 42.0 | ± 12 | ± 1750 | 150 | 80 |
GA030-D15 | 42.0 | ± 15 | ± 1400 | 150 | 80 |
GA030-D24 | 42.0 | ± 24 | ± 875 | 240 | 80 |
GA030-D0305 | 26.5 | Vo1 = +3.3, Vo2 = +5 | Io1 = 5000, Io2 = 2000 | 150 (Vo1) 240 (Vo2) | 72 |
GA030-D0512 | 40.0 | Vo1 = +5, Vo2 = +12 | Io1 = 5000, Io2 = 1250 | 75 | |
GA030-D0515 | 40.0 | Vo1 = +5, Vo2 = +15 | Io1 = 5000, Io2 = 1000 | 75 | |
GA030-D0524 | 40.0 | Vo1 = +5, Vo2 = +24 | Io1 = 5000, Io2 = 625 | 78 |
Parameters | Conditions | Min | Typ | Max | Units | |
---|---|---|---|---|---|---|
Rated Input Voltage | Vo, Io nom | 100 ~ 240 | Vac | |||
Voltage Range | Vo, Io nom | AC in | 90 | 264 | Vac | |
DC in | 120 | 370 | Vdc | |||
Line Frequency | Vi nom, Io nom | 47 | 50/60 | 63 | Hz | |
Inrush Current | Io nom | Vi: 115VAC | 12 | A | ||
Vi: 230VAC | 20 | A | ||||
Input Fuse | VDE / UL / CCC FUSE 2.5A / 250V (Slow blow) |
Parameters | Conditions | Min | Typ | Max | Units | |
---|---|---|---|---|---|---|
Output Voltage Accuracy | Vi nom, Io nom (Single output) | 3.3V....9V Models | ± 3 | % | ||
10....48V Models | ± 2 | |||||
Dual Output | ± 5 | % | ||||
Minimum Load | Vi nom | Single Output Models | 0 | % | ||
Dual Output Models (each output) | 20 | % | ||||
Line Regulation | Io nom, Vi min....Vi max | ± 1 | % | |||
Load Regulation | Io min ~ Io nom | Single Output Models | ± 2 | % | ||
Dual Output Models | ± 5 | % | ||||
Transient Recovery Time | Vi nom, Io nom = ← → 0.5 Io nom | 1000 | us | |||
Protection | Over load | Above 110% rated output power | ||||
Protection type: Recovers automatically after fault condition is removed | ||||||
Short circuit | Recovers automatically after fault condition is removed | |||||
Over Voltage (Main Output) | 120%-150% rated output Voltage | |||||
Protection type: Zener diode clamp |
Notes:
Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.
Parameters | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|
Switching Frequency | Vi nom, Io nom | 65 | KHz | ||
Isolation Voltage | Input / Output | 3KVac / 5mA / 5Secs | |||
Isolation Resistance | Input / Output, @500 Vdc | 100 | MΩ; | ||
Operating Temperature | Operating at Vi nom, Io nom | -20 | +70 | ℃ | |
Derating | Vi nom, Io nom +51 to 71℃ | 2 | % / ℃ | ||
Storage Temperature | Non Operational | -40 | +85 | ℃ | |
Relative Humidity | Vi nom, Io nom | 95 | % RH | ||
Safety Standards | EN62368-1 approved | ||||
EMI Conduction & Radiation | Compliance to EN55032 | ||||
EMS Immunity | Compliance to EN55024 | ||||
Dimension | L 88.90 x W 63.50 x H 31.75 mm L 3.5 x W 2.5 x H 1.25 inches | ||||
Cooling | Free air convection |
Dimension
Files Download GA030-Series.pdf
26~48W 3KVac Isolation Regulated Output AC to DC Power Conversion
Universal input 90~264VAC.
High efficiency up to 88%.
Protection: short circuit/overload/over voltage.
Fully encapsulated plastic case.
Internal input filter.
3 years warranty.
ROHS compliant.
Part Number | Output Wattage | Output Voltage | Output Current | Ripple & Noise | Efficiency |
---|---|---|---|---|---|
(W) | (VDC) | (mA) | (mV) max (Note) | (TYP %) | |
GA030-S03 | 26.4 | 3.3 | 8000 | 150 | 72 |
GA030-S05 | 40.0 | 5 | 8000 | 150 | 75 |
GA030-S06 | 40.0 | 6 | 6650 | 150 | 75 |
GA030-S07 | 40.0 | 7 | 5700 | 150 | 80 |
GA030-S08 | 40.0 | 8 | 5000 | 150 | 80 |
GA030-S09 | 40.0 | 9 | 4400 | 150 | 82 |
GA030-S10 | 40.0 | 10 | 4000 | 150 | 82 |
GA030-S12 | 42.0 | 12 | 3500 | 150 | 84 |
GA030-S13 | 42.0 | 13 | 3200 | 150 | 84 |
GA030-S14 | 42.0 | 14 | 3000 | 150 | 84 |
GA030-S15 | 42.0 | 15 | 2800 | 150 | 84 |
GA030-S16 | 42.0 | 16 | 2625 | 150 | 85 |
GA030-S18 | 42.0 | 18 | 2300 | 150 | 85 |
GA030-S24 | 42.0 | 24 | 1750 | 240 | 86 |
GA030-S27 | 42.0 | 27 | 1550 | 240 | 86 |
GA030-S36 | 43.2 | 36 | 1200 | 240 | 86 |
GA030-S48 | 48.0 | 48 | 1000 | 240 | 88 |
GA030-D05 | 40.0 | ± 5 | ± 4000 | 150 | 75 |
GA030-D12 | 42.0 | ± 12 | ± 1750 | 150 | 80 |
GA030-D15 | 42.0 | ± 15 | ± 1400 | 150 | 80 |
GA030-D24 | 42.0 | ± 24 | ± 875 | 240 | 80 |
GA030-D0305 | 26.5 | Vo1 = +3.3, Vo2 = +5 | Io1 = 5000, Io2 = 2000 | 150 (Vo1) 240 (Vo2) | 72 |
GA030-D0512 | 40.0 | Vo1 = +5, Vo2 = +12 | Io1 = 5000, Io2 = 1250 | 75 | |
GA030-D0515 | 40.0 | Vo1 = +5, Vo2 = +15 | Io1 = 5000, Io2 = 1000 | 75 | |
GA030-D0524 | 40.0 | Vo1 = +5, Vo2 = +24 | Io1 = 5000, Io2 = 625 | 78 |
Parameters | Conditions | Min | Typ | Max | Units | |
---|---|---|---|---|---|---|
Rated Input Voltage | Vo, Io nom | 100 ~ 240 | Vac | |||
Voltage Range | Vo, Io nom | AC in | 90 | 264 | Vac | |
DC in | 120 | 370 | Vdc | |||
Line Frequency | Vi nom, Io nom | 47 | 50/60 | 63 | Hz | |
Inrush Current | Io nom | Vi: 115VAC | 12 | A | ||
Vi: 230VAC | 20 | A | ||||
Input Fuse | VDE / UL / CCC FUSE 2.5A / 250V (Slow blow) |
Parameters | Conditions | Min | Typ | Max | Units | |
---|---|---|---|---|---|---|
Output Voltage Accuracy | Vi nom, Io nom (Single output) | 3.3V....9V Models | ± 3 | % | ||
10....48V Models | ± 2 | |||||
Dual Output | ± 5 | % | ||||
Minimum Load | Vi nom | Single Output Models | 0 | % | ||
Dual Output Models (each output) | 20 | % | ||||
Line Regulation | Io nom, Vi min....Vi max | ± 1 | % | |||
Load Regulation | Io min ~ Io nom | Single Output Models | ± 2 | % | ||
Dual Output Models | ± 5 | % | ||||
Transient Recovery Time | Vi nom, Io nom = ← → 0.5 Io nom | 1000 | us | |||
Protection | Over load | Above 110% rated output power | ||||
Protection type: Recovers automatically after fault condition is removed | ||||||
Short circuit | Recovers automatically after fault condition is removed | |||||
Over Voltage (Main Output) | 120%-150% rated output Voltage | |||||
Protection type: Zener diode clamp |
Notes:
Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.
Parameters | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|
Switching Frequency | Vi nom, Io nom | 65 | KHz | ||
Isolation Voltage | Input / Output | 3KVac / 5mA / 5Secs | |||
Isolation Resistance | Input / Output, @500 Vdc | 100 | MΩ; | ||
Operating Temperature | Operating at Vi nom, Io nom | -20 | +70 | ℃ | |
Derating | Vi nom, Io nom +51 to 71℃ | 2 | % / ℃ | ||
Storage Temperature | Non Operational | -40 | +85 | ℃ | |
Relative Humidity | Vi nom, Io nom | 95 | % RH | ||
Safety Standards | EN62368-1 approved | ||||
EMI Conduction & Radiation | Compliance to EN55032 | ||||
EMS Immunity | Compliance to EN55024 | ||||
Dimension | L 88.90 x W 63.50 x H 31.75 mm L 3.5 x W 2.5 x H 1.25 inches | ||||
Cooling | Free air convection |
Dimension
Files Download GA030-Series.pdf