Non-isolated Wide Voltage Input Range POL DC to DC Converter

Features :


3PIN SIP Package

Pin-out compatible with LM78XX Linear regulators

Wide Input Voltage Range 4.75~36VDC

Efficiency up to 97%,Non isolated, no need for heatsink

Regulated Output Types

Short Circuit Protection

Operating Temperature: -40℃ to +97℃

UL94V-0 Package Material

100% Burned In

3 Years Warranty





Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Input Range Output Voltage Output Current Efficiency Capacitive Load Max
Vdc Vdc mA Min.Vin
(%)TYP
Max.Vin
(%)TYP
μF
01D-2R5-3AF 4.75-26 2.5 3000 93 84 3000
01D-3R3-3AF 4.75-26 3.3 3000 90 87 3000
01D-05-3AF 7-26 5.0 3000 95 90 3000
01D-12-3AF 15-36 12 3000 96 94 1800
01D-15-3AF 18-36 15 3000 97 94 1200


Input Specifications


Parameters Conditions Min Typ Max Units
Input Voltage See models table 4.75   36 Vdc
No Load Input Current All models, Max. Vin   25 30 mA
Max i mum Input Current Mini.Vin,
Full Load
01D-2R5-3AF     1698 mA
01D-3R3-3AF     2316
01D-05-3AF     2256
01D-12-3AF     2500
01D-15-3AF     2577
Start up Time
100% Load 01D-2R5-3AF
01D-3R3-3AF
01D-05-3AF
  10   ms
01D-12-3AF
01D-15-3AF
  14  
Input Filter All Models Internal Capacitor


Output Specifications


Parameters Conditions Min Typ Max Units
Voltage Tolerance 100% Load   ±2   %
Line Regulation Vin(min) to Vin(max)
@100% Load
-0.2   +0.2 %
Load Regulation 0% Load to 100% Load -0.8   +0.8 %
Minimum Load Not Required
Ripple & Noise
(BW=20MHz)
Without
Output
Capacitor
01D-2R5-3AF,
01D-3R3-3AF
    50 mVp-p
01D-05-3AF     75
01D-12-3AF,
01D-15-3AF
    150
Transient Response Setting Time 50 % Load Step Change
(upper half)
  150   us
Transient Response Deviation 50 % Load Step C hange
(upper half)
  250   %
Current Limit % of Io, Hiccup mode,
Auto recovery
180      %
Short Circuit Protection Continuous [ Hiccup Mode] ,Auto Recovery
Temperature Coefficient
-0.02   +0.02 %/℃


General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency 100% Load, Nominal Input   310   KHz
Operating
Ambient Temperature
(Power Derating
See Derating Graph)
Max. Vin,
100% Load
01D-2R5-3AF -40   72.1
01D-3R3-3AF   71.0
01D-05-3AF   66.7
01D-12-3AF   52.1
01D-15-3AF   38.9
Thermal
Impedance
20LFM   None   ℃/W
100LFM   None  
200LFM   None  
400LFM   None  
Maximum
Case Temperature
    None  
Storage
Temperature
  -55   125
Relative
Humidity
Non Condensing 5%   95% RH
Cooling Natural Convection
Thermal Shock MIL-STD-810F
Shock &Vibration Test MIL-STD-810F
Case Material Open frame
Potting Material None
MTBF MIL-HDBK-217F@25℃ (calculated) 5.16X106 Hours
Weight   10 g
Dimensions 14.9x9.5x18.4 mm